Set Access Ctrl

Set Access Control allows you to change security

configuration. This function is protected by an
Administrative Password. The Reset Security function
allows you to reset the Administrative Password, but
results in erasure of the modem’s security database.

To access Security from the Top-Level menu, make the

following selections:

F1

Idle : 19.2
Control Security

F2

F3

Press the

key until Security appears. Select Security.

Set Access Control allows you to configure critical

parameters contained within the security database table
that control dial access security. These parameters are
protected by an Administrative Password, which is an
8-digit decimal number.

Set Access Control contains the Edit Password Table,

Set Answer Security, Set Originate Security, and Set
Administrative Password security configuration groups.
These groups do not appear on the LCD until the correct
Administrative Password is entered.

Administrative Password

The Administrative Password is an 8-digit decimal

number password that allows only authorized users to
access Security branch functionality. This password must
be entered every time you access the Security branch.
This feature is shipped from the factory with the
Administrative Password set to 00000000.

Once the correct Administrative Password is entered,

the Edit Password Table, Set Answer Security, Set
Originate Security, and Set Administrative Password
groups can be displayed on the LCD.

To enter your Administrative Password from

Set_Access_Ctrl, make the following selections:

F1

Security

>

Set_Access_Ctrl

F2

F3

Select Set_Access_Ctrl from the Security branch.

F1

Admin Password?
Ent

ą Ą"

00000000

F2

F3

The Administrative Password appears. This occurs

every time you enter the Security branch.

Select the F2 (

") key to increment password values.

Press the

key to move the cursor to the next

position.

Continue this sequence until the full Administrative

Password value appears and then press Ent.

F1

Set Access Ctrl

>

Edit PassWd Table

F2

F3

If the correct value is entered, the EditPassWdTable

group appears on the LCD.

Press the

key to scroll the Set Answer Security, Set

Originate Security, and Set Administrative Password
groups into view.

If an incorrect administrative password is entered, then

the message PassWrd Invalid appears as well as the last
password entered. Enter the correct password value or

press the

or

key to exit the Security branch.