AT Command Set and S-Registers

14-21

3810-A2-GB30-20

November 1996

Table 14-2

(6 of 11)

3800 Series S-Registers

S-Register

Front Panel Branch

Description

S47

Auto Dial Standby
Register determines if the modem performs an automatic dial standby if
in Dial Backup mode.

Register has the following values:

0 = Disable
1 = 15 minutes
2 = 1 hour
3 = 4 hours

255 = Test(2min)

Factory setting is Disable.

Configure\Edit\Leased Line

S48

Leased-Line Carrier On Level
Register determines if the modem disconnects if the carrier signal on
leased lines falls below – 26 dBm or – 43 dBm.

Register has the following values:

0 = – 43 dBm
1 = – 26 dBm

Factory setting is – 43 dBm.

Configure\Edit\Leased Line

S49

Transmit Buffer Disconnect Delay
Determines the maximum amount of time the modem can continue to
send data in its Transmit Buffer to the remote modem after it is
commanded by the DTE to disconnect.

Register has the following values:

S49 = 0

Disable (Immediate disconnect)

S49 = 1

1 second

S49 = 2

2 seconds

S

S

S

S

S49 = 255

255 seconds

Factory setting is 10 seconds.

Configure\Edit\
V42/MNP/Buffer

S51

DTE RL (CT140)
Register determines if the modem performs a remote digital loopback if it
receives a CT140 signal from the DTE.

Register has the following values:

0 = Disable
1 = Enable

Factory setting is Disable.

Configure\Edit\Tests

S52

DTE LL (CT141)
Register determines if the modem performs a local analog loopback if it
receives a CT141 signal from the DTE.

Register has the following values:

0 = Disable
1 = Enable

Factory setting is Disable.

Configure\Edit\Tests