beautypg.com

Paradyne 3810 User Manual

Page 159

background image

AT Command Set and S-Registers

14-25

3810-A2-GB30-20

November 1996

Table 14-2

(10 of 11)

3800 Series S-Registers

S-Register

Front Panel Branch

Description

S80

No Data Disconnect Trigger Signal
Register determines whether Pin 2 (transmit data) or Pin 3 (receive data)
of the modem’s RS-232 serial interface is monitored so that the modem
can disconnect the call if there is no activity for a certain period. (See the
\T command.)

Register has the following values:

0 = Transmit or Receive
1 = Transmit only
2 = Receive only
3 = Transmit and Receive

Factory setting is 3.

Configure\Edit\Line Dialer

S82

V.32bis Autorate (Leased Line)
Register determines if Autorating is used on leased lines when
connected in V.32bis mode.

Register has the following values:

0 = Enable
1 = Disable

Factory setting is Enable.

Configure\Edit\Leased Line

S83

MI/MIC Dialing
Register determines if MI/MIC control leads can be used to force the
modem into the originate handshake after first dialing a call.

Register has the following values:

0 = Disable
1 = Enable

Factory setting is Disable.

Configure\Edit\Line Dialer

S84

AT Command Mode
Register determines how the modem responds to valid and invalid AT
commands.

Register has the following values:

0 = Normal
1 = No ERROR
2 = No Strap or ERROR

Factory setting is Normal.

Configure\Edit\DTE Dialer

S85

Fast Disconnect
Register allows the modem to disconnect immediately after receiving a
disconnect command from a local DTE or its own diagnostic control
panel.

Register has the following values:

0 = Disable
1 = Enable

Factory setting is Disable.

Configure\Edit\Line Dialer