beautypg.com

Options, Record – Paradyne 3810 User Manual

Page 55

background image

Status Branch

7-5

3810-A2-GB30-20

November 1996

Options

The Options Status function displays all optional

firmware features currently installed in the modem (for
example, V.29, V.33, and dial network management). If no
firmware options are installed, None_Installed appears on
the LCD.

To access Options from the Status branch, make the

following sections:

F1

Status:
RS366A

Options

F2

F3

Press the

key until Options appears. Select

Options.

F1

Options’ Status

>

V.29 V.33

F2

F3

If optional features are installed in the modem, they

appear on the LCD’s bottom line. If other features are
installed, press the

key to scroll other features into

view.

Record

Record is a troubleshooting tool used by the end user in

conjunction with support personnel. This function allows
the end user to retrieve and report any sequence faults to
support personnel. A sequence fault is an irregular or
unexpected event.

There are two selections under Record: Display and

Clear. Display allows up to eight sequence fault messages
that have been recorded by the modem to be displayed on
the LCD. If no sequence faults have occurred, then
Modem O.K. appears.

Clear is used to remove all sequence fault messages

from nonvolatile memory and the LCD.

To access Record from the Status branch, make the

following selections:

F1

Status

<

Options Record

F2

F3

Press the

key until Record appears. Select Record.

F1

Record Status
Display Clear

F2

F3

To display sequence faults, select Display.

F1

Record Number 1
Modem O.K.

F2

F3

The LCD displays the first sequence fault field.

(Sequence fault fields range from 1 to 8 and are identified
by a number in the upper right corner.) Press the

key

to view the remaining fields. The message Modem O.K.
appears if no sequence faults have occurred.

To remove sequence fault records from both the LCD

and nonvolatile memory, select Clear. The message
Modem O.K. appears.

To exit this function and remain in the Status branch,

press the

key. To exit and return to the Top-Level

menu, press the

key.

AT Command Equivalent