Messages and Troubleshooting

8

Overview

There are many messages available to help you assess the status of the device
and contribute to problem resolutions. Refer to the following sections:

H

Configuring SNMP Traps

H

Device Messages

H

Troubleshooting

Configuring SNMP Traps

An SNMP trap can be automatically sent out through the IMC or the 10BaseT
port to the SNMP manager when the DSU detects conditions set by the user.
These traps enable the SNMP manager to gauge the state of the network. Refer
to Appendix D,

Standards Compliance for SNMP Traps

,

for details of SNMP traps

supported by the DSU.

To configure the DSU for SNMP traps, use the SNMP Traps Options screen to:

H

Enable SNMP traps.

H

Set the number of SNMP managers that receive SNMP traps from the DSU.

H

Enter an IP address and network destination for each SNMP manager
specified.

H

Select the type of SNMP traps to be sent from the DSU.

To configure SNMP Traps, follow this menu selection sequence:

Main Menu

Configuration

Load Configuration From

Edit

SNMP

SNMP Traps

Refer to Table A-9,

SNMP Traps Options

.