Standards compliance for snmp traps, Overview, Trap: warmstart – Paradyne 7612 SNMP DSU User Manual
Page 105: Trap: authentificationfailure, Appendix d, To appendix d, For details of snmp traps, Refer to appendix d

D-1
7612-A2-GB20-10
November 1997
Standards Compliance for
SNMP Traps
D
Overview
This appendix describes the unit’s compliance with SNMP standards and any
special operational features for the SNMP traps supported. The unit supports
user interface traps and enterprise-specific traps.
Trap: warmStart
SNMP Trap
Description
Possible Cause
warmStart
The unit has reinitialized itself.
The trap is sent after the unit
resets itself and stabilizes.
There are no variable-bindings.
H
Reset command.
H
Power disruption.
Trap: authentificationFailure
SNMP Trap
Description
Possible Cause
authenticationFailure Failed attempts to access the
unit.
There are no variable-bindings.
H
SNMP message not properly
authenticated.
H
Three unsuccessful attempts
were made to enter a correct
login/password combination.
H
IP address security is
enabled, and a message was
received from SNMP
manager whose address was
not on the list of approved
managers.