Laser:enable:outoff – Lightwave Communications LDX-3232 User Manual
Page 74

C O M M A N D R E F E R E N C E
LDX-3232 Device-Dependent Command Reference
58
LDX-3232
C H A P T E R
4
The LASer:ENABle:OUTOFF command sets the status outoff enable register of the
LASER operations (things that will turn the LASER output off).
Syntax Diagram
Parameters
An
Notes
The enabled LASER outoff bits can be read by using the LASer:ENABle:OUTOFF?
query.
The enable registers normally retain their values at power-up (as they were at power-
down) unless the power-on status clear flag is set true (for more information see the
*PSC definition, in the GPIB-IEEE488 specification).
The factory default value for this register is #B0000100000001000, #H808, or 2056
decimal.
Examples
"LAS:ENAB:OUTOFF 9" -action: enables the LASER status outoff register so that Power
limit and LASER current limit conditions will cause the LASER output to be turned off.
"Las:Enab:Outoff #HE0B" -action: enables the LASER status outoff register so that any
or all of the above conditions will cause the LASER output to be turned off.
LASer:ENABle:OUTOFF
F
RONT
P
ANEL
R
EMOTE
1
LASER Current Limit
256
N/A
2
LASER Voltage Limit
512
Output is out of tolerance*
4
N/A
1024
N/A
8
Power limit (with output on)
2048
N/A
16
N/A
4096
N/A
32
N/A
8192
N/A
64
N/A
16384
N/A
128
N/A
32768
N/A
:
LAS
space> value> : ENAB : OUTOFF