beautypg.com

Lightwave Communications LDX-3232 User Manual

Page 52

background image

C O M M A N D R E F E R E N C E

36

LDX-3232

C H A P T E R

4

Name

Parameters

Function

LAS:CAL:MDI?

NONE

Returns the ready state for entering the monitor
photodiode current calibration value

LAS:COND?

NONE

Returns the value of the LASER condition register

LAS:DEC

0, 1 or 2

Used to decreate the laser current setpoint value by one
or more steps

LAS:DIS

1

Turns the LASER display on or off

LAS:DIS?

NONE

Returns the LASER display value

LAS:DIS:LDI

NONE

Turn on/off LASER display to show laser output current

LAS:DIS:LDI?

NONE

Returns status of laser output current display, on/off

LAS:DIS:LDV

NONE

Turn on/off LASER display to show laser output voltage

LAS:DIS:LDV?

NONE

Returns status of laser output voltage display, on/off

LAS:DIS:MDI

NONE

Turn on/off LASER display to show photodiode monitor
current

LAS:DIS:MDI?

NONE

Returns status of photo diode monitor current display,
on/off

LAS:DIS:MDP

NONE

Turns on/off LASER display to show photodiode monitor
power

LAS:DIS:MDP?

NONE

Returns status of photodiode monitor power display,
on/off

LAS:DIS:PARAM

NONE

Enables LASER display to show parameter values

LAS:DIS:SET

NONE

Shows the LASER display setpoint corresponding to
mode

LAS:DIS:SET?

NONE

Returns status of LASER setpoint display, on/off

LAS:ENAB:COND

1

Sets the enable register for LASER conditions

LAS:ENAB:COND?

NONE

Returns the value of the LAS conditions enable register

LAS:ENAB:EVE

1

Sets the enable register for LAS events

LAS:ENAB:EVE?

NONE

Returns the value of the LAS event enable register

LAS:ENAB:OUTOFF

1

Sets the enable register for LAS conditions, that turn the
LAS output off

LAS:ENAB:OUTOFF?

NONE

Returns the value of the LAS outoff enable register

LAS:EVENT?

NONE

Returns the value of the LAS event register

LAS:LDI

1

Used to set the LASER constant current source setpoint
value

LAS:LDI?

NONE

Used to return the constant current source measured
value

LAS:INC

0, 1, or 2

Used to increment the LASER setpoint value by one or
more steps

LAS:LDV

1

Used to set the laser voltage value for calibration

LAS:LDV?

NONE

Used to return the measured laser voltage value