beautypg.com

Error messages – Lightwave Communications LDX-3232 User Manual

Page 117

background image

C A L I B R A T I O N A N D T R O U B L E S H O O T I N G

Error Messages

04_06

LDX-3232

101

C H A P T E R

6

Error Messages

In the event of a hardware error condition, error messages will be displayed on the
display. In most cases, the error message will appear for three seconds. In some
cases the error code display will remain until the user changes display modes. In
the case of multiple error messages, the display may sequentially show each
message for three seconds. In addition to the hardware errors, GPIB errors may
be read via the ERR? query. Table 3.4 lists the numerical error ranges by function.
Table 3.5 contains all of the error messages that may be generated. Not all of
these messages may appear on the front panel displays. Some refer to GPIB
activities only.

In remote operation, the errors can be read by issuing the ERR? query. When this
is done, all of the error messages that are resident in the error queue are returned
(up to 10 may be stored). Reading the error queue via GPIB clears the error
queue.

Table 6.3 Error Code Classifications

Table 6.4 LDX-3232 Series Error Codes

Error Code Range

Area of Operation

E-001 to E-099

Internal Program Errors

E-100 to E-199

Parser Errors

E-200 to E-299

Execution Control Errors

E-300 to E-399

GPIB Errors

E-500 to E-599

LASER Control Errors

Error Code

Explanation

E-001

Memory allocation failure

E-103

length too long

E-104

type not defined

E-105

exponent not valid

E-106

digit expected

E-123

Command not found

E-124

Lookup, failed because query/command type match failed

E-126

Too few or too many program data elements

E-201

value out of range

E-202

will not convert to valid type