Lightwave Communications LDX-3232 User Manual
Page 46
R E M O T E O P E R A T I O N
Status Reporting
30
LDX-3232
C H A P T E R
3
Output Off Register
The Output Off Enable Register allows you to determine that conditions and
events in the LDX-3232 High Compliance Current Source can cause the current
source output to be turned off. This reigster is configured in a manner similar to
the status reporting registers. However, the register output is not reported in the
Status Byte Register. Rather, it sets the hardware that controls the output
switching. The events and conditions that may be set to cause the current source
output to be turned off are shown in Figure 3.3.
The default (factory) settings for this register are shown in Table 3.3. These
settings are not affected by the *PSC (Power-On Status Clear) command.
Table 3.3 LDX-3232 Series Default Settings for Output Off Registers
0 - disabled
8 - N/A
1 - disabled
9 - disabled
2 - N/A
10 - N/A
3 - enabled
11 - N/A
4 - N/A
12 - N/A
5 - N/A
13 - N/A
6 - N/A
14 - N/A
7 - N/A
15 - N/A