beautypg.com

Lightwave Communications LDX-3232 User Manual

Page 49

background image

R E M O T E O P E R A T I O N

Error Messages

04_06

LDX-3232

33

C H A P T E R

3

(up to 10 may be stored). Reading the error queue via GPIB clears the error
queue.

Table 3.4 Error Code Classifications

Table 3.5 LDX-3232 Series Error Codes

Error Code Range

Area of Operation

E-001 to E-099

Internal Program Errors

E-100 to E-199

Parser Errors

E-200 to E-299

Execution Control Errors

E-300 to E-399

GPIB Errors

E-500 to E-599

LASER Control Errors

Error Code

Explanation

E-001

Memory allocation failure

E-103

length too long

E-104

type not defined

E-105

exponent not valid

E-106

digit expected

E-123

Command not found

E-124

Lookup, failed because query/command type match failed

E-126

Too few or too many program data elements

E-201

value out of range

E-202

will not convert to valid type

E-203

Security violation, command is not available without clearance

E-205

is not a Boolean value or word

E-207

will not convert to an unsigned 16-bit value

E-209

will not convert to an unsigned 32-bit value

E-210

will not convert to a floating point value

E-211

will not convert to a character value

E-213

is incorrect block data length

E-214

length exceeds maximum

E-302

Query error; device was addressed to talk, but GPIB controller failed to read all of the