6-8

A-61140 January 2000

Code

Message Displayed

Description/Action Required

E251

Rear illumination failure

A rear lamp failure was detected while the rear lamp
was illuminated. Press Cal to calibrate the scanner. If
the error persists, verify the optical path is free of
obstructions, clean the imaging guides and replace
the front and rear lamps.

E261

Fr Cal illumination failure

A front lamp failure was detected during calibration.
Press Jog to remove the calibration target. Press
Cal and try to calibrate the scanner again. If the error
persists, verify the optical path is free of obstructions,
clean the imaging guides and replace the front and
rear (duplex scanners) lamps.

E262

Rr Cal illumination failure

A rear lamp failure was detected during calibration.
Press Jog to remove the calibration target. Press
Cal and try to calibrate the scanner again. If the error
persists, verify the optical path is free of obstructions,
clean the imaging guides and replace the front and
rear lamps.

E263

Calibration target too short

Tried to use a calibration target shorter than 12
inches. Press Jog to remove the calibration target.
Use the appropriate calibration target. Press Cal and
try the calibration process again.

E264

Cal target front too dark

Tried to use a calibration target where the front side is
darker than the specification allows. Press Jog to
remove the calibration target. Use the appropriate
calibration target. Press Cal and try the calibration
process again.

E265

Cal target rear too dark

Tried to use a calibration target where the rear side is
darker than the specification allows. Press Jog to
remove the calibration target. Use the appropriate
calibration target. Press Cal and try the calibration
process again.

E278

Re-scan - doc feed error

A document has been fed which is off-center or
skewed. Press Run to restart the transport system.

E291

Scanner disabled

Tried to run the transport system when the scanner
was disabled (other than via the Count Only function).
Enable the scanner from the host and press Run.

E294

Fr Cal Fail - calibration reqrd

A calibration failure was detected in the front scan
module. Press Cal to calibrate the scanner. If the
error persists, verify the optical path is free of
obstructions, clean the imaging guides and replace
the front and rear (duplex scanners) lamps.