beautypg.com

Operator message listing – Kodak 7520 User Manual

Page 59

background image

A-61140 January 2000

6-3

Operator message listing

Code

Message Displayed

Description/Action Required

E101

Auto shut-off

Transport will stop and the message will be displayed
if a document has not been scanned within one
minute. Press Run to continue. Feed documents.

E102

Press STOP and try again

Tried to use a function code that is not valid while the
transport is running. Press Stop and try again.

E103

Select valid mode (1 - 18)

Invalid application mode was selected. Enter function
code F01 to select another mode.

E104

Function not available

Invalid function code entered. Enter a valid function
code.

E105

Parameter Value Invalid

There is an invalid front/rear resolution mismatch or a
crop length/resolution mismatch. Check the scanner
configuration.

E106

Doc length monitor - warning

Tried to scan a document that was shorter or longer
than the maximum or minimum length set up for the
application mode you are using. Potentially a multi-
feed condition. Check the document length to see if it
is shorter than the minimum or longer than the
maximum allowed or a multi-feed; refeed the
document.

E107

Doc skew monitor - warning

Tried to scan a document that is skewed greater than
the maximum skew angle set up for the application
mode you are using and less than 30 degrees.
Refeed the document.

E112

Invalid patch level

Invalid patch was used. The patch document is
ignored and the previous image level and image
address remain unchanged. Feed a correct patch
document.

E113

Incorrect image address

Tried to use an invalid image address. The image
address was not completely input before pressing
Enter. Press Next to enter a correct image address.

E114

Check current IA/level

Conflicting input regarding the proper level was
received. Check the current document image level
and image address.

E116

Accessory not mode enabled

Tried to use an accessory that is not enabled in the
chosen mode. Enter a different function code or
select an application mode that is enabled. If the
selected accessory is desired, contact Service to
change the mode configuration.