4. Lift up and latch the horizontal transport plate into its open position.

NOTE: If the Patch Reader accessory is installed, it must be

removed from the mounting plate in order to lift up the
horizontal transport plate.

5. Rotate the feed roller downward and clean with a water-moistened

cloth. Continue cleaning until all residue is removed from the roller
ribs.

6. Clean the surface of the feed roller assembly with a dry cloth.

7. Clean the separator roller with a dry cloth.

IMPORTANT: You can only rotate the separator roller outward

(toward you). Do not try to rotate it in the opposite
direction or you could damage the separator roller
assembly.

8. Dry all cleaned areas with a dry, lint-free cloth.

9. Rotate the feed roller cover down to its original position.

10. Lower the release bar and latch the front scan module in its original

position.

11. Close the lower access door.