beautypg.com

Kodak 7520 User Manual

Page 63

background image

A-61140 January 2000

6-7

Code

Message Displayed

Description/Action Required

E234

Press JOG to remove docs

When pressing Run, a document was detected
under a document sensor. Press Jog to move all
documents in the transport system, then press Run
and rescan any documents that have not been
scanned.

E235

Controlled power-down reqrd

This message is displayed along with a more detailed
error message.

Turn the side panel switch off.

Turn the main power switch off.

Wait 5 to 10 seconds.

Turn the main power switch on.

Turn the side panel switch on.

If the error repeats, call Service.

E241

Enter correct IA, re-scan

The patch document fed conflicts with the Level key
pressed. Verify the current image level and image
address. If necessary, alter the image level or image
address using the Level keys or Next key or press
Run and rescan the patch document.

E244

Enter correct IA, re-scan

The T-patch document was fed and then followed by
a 2-patch or 3-patch document which conflicted with
the level of the T-patch. Verify the current image level
and image address. If necessary, alter the image
level or image address using the Level keys, or Next
key or press Run and rescan the T-patch,
2-patch or 3-patch document.

E245

Enter correct IA, re-scan

Two T-patch documents were fed one right after the
other. Verify the current image level and image
address. If necessary, alter the image level or image
address using the Level keys or Next key. Do not
scan another T-patch document.

E246

Enter correct IA, re-scan

The T-patch document fed conflicts with the level of
the image address entered. Verify the current image
level and image address and if necessary, alter the
image level or image address using the Level keys or
Next key. Do not scan another T-patch document.

E250

Frnt illumination failure

A front lamp failure was detected while the front lamp
was illuminated. Press Cal to calibrate the scanner. If
the error persists, verify the optical path is free of
obstructions, clean the imaging guides and replace
the front and rear (duplex scanners) lamps.