A-41069 January 1993

Trouble

Clear streak on scanned
images.

Overall scanned image density
too light, too dark, or uneven.

Calibration failure.

Probable Cause

Remedy

Foreign object in the optical path.

Refer to Section 8.
Check and clean imaging
guides and transport area.

Dust or dirt on mirrors or imaging

Refer to Section 8.

Check and
guides.

clean imaging guides and
mirrors.

Calibration not performed or not

Refer to Section 3. Perform

performed correctly.

calibration using instructions
provided.

Lamps are dirty or not properly

Refer to Section 8. Check the

installed.

lamps for proper installation.
Check for dirt or debris in the
lamp housing.

Calibration target skewed when

Retry. Adjust feed tray

feeding.

side guides. Adjust

feed and

separator roller gap.

Lamps are dirty or not properly

Refer to Section 8. Check the

installed.

lamps for proper installation.
Check for dirt or debris in the
lamp housing.

Document in the transport at the

Refer to Section 7.

Remove
time of calibration.

any documents in the transport
system. Retry.