62

Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001

Workgroup Configurations

The following configuration rules apply to array workgroup configurations
(

FIGURE 6-3

):

The interconnect ports, which are used only in partner group configurations,
cannot be used for host connections.

The FC-AL connection provides a data path to the application host.

The Ethernet connection provides a link to the management host.

The serial port is used solely for diagnostics and service by qualified service
personnel only.

Fiber-optic cable lengths between 2 and 500 meters, using short-wave laser and
50-micron fiber-optic cable, are supported.

FIGURE 6-3

Array Workgroup Configuration

Application host

Ethernet port

Ethernet

FC-AL
connection

LAN

Management host

connection