Switch connection where the FC-AL from the array is connected to a switch on
the same network as the data host.

Administration Path

For the administration path, each controller unit has an Ethernet connector. For each
installed controller, an Ethernet connection and IP address are required. The
administration server uses this link to set up and manage the arrays using Sun
StorEdge Component Manager software.

Note –

In a partner group, only one of the two Ethernet connections is active at any

time. The second Ethernet connection is used for redundancy.

Connecting Partner Groups

The array also has two interconnect cards that are used to connect the array in a
partner group. These interconnect cards have two ports (in and out).

Note –

Partner groups are not supported in Sun Cluster 2.2.

Note –

In a workgroup (standalone) configuration, these interconnect cards cannot

be used to connect to the administrative console or to the application host. These
interconnect cards are used solely for ensuring redundancy and failover mechanisms
in partner groups.

FIGURE 6-1

and

FIGURE 6-2

show a Sun StorEdge T3 and T3+ array with a controller

card and interconnect cards.