Chapter 4

Configuration Examples

29

Single Host With Two Controller Units
Configured as a Partner Group

FIGURE 4-2

shows one application host connected through FC-AL cables to one array

partner group, which consists of two Sun StorEdge T3+ arrays. The Ethernet
connection from the master controller unit is on a public or separate network and
requires an IP address for the partner group. In the event of a failover, the alternate
master controller unit will use the master controller unit’s IP address and MAC
address.

FIGURE 4-2

Single Host With Two Controller Units Configured as a Partner Group

This configuration is a recommended enterprise configuration for RAS functionality
because there is no single point of failure. This configuration supports Dynamic
Multi-Pathing (DMP) by VERITAS Volume Manager, the Alternate Pathing (AP)
software in the Solaris operating environment, or Sun StorEdge Traffic Manager
software for failover only.

The following three global parameters must be set on the master controller unit, as
follows:

mp_support

= rw or mpxio

cache mode

= auto

cache mirroring

= auto

For information on setting these parameters, refer to the Sun StorEdge T3 and T3+
Array Administrator’s Guide
.

Application host

FC-AL connection

Interconnect
cables

LAN

Ethernet port

Ethernet
connection

Management host

HBAs

Ethernet
connection

Master

Alternate
master
controller

controller

unit

unit