Supported software, Sun cluster support – Sun Microsystems Sun StorEdge T3 User Manual
Page 22
10
Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001
Supported Software
The following software is supported on Sun StorEdge T3 and T3+ arrays:
■
Solaris 2.6, Solaris 7, and Solaris 8 operating environments
■
VERITAS Volume Manager 3.04 and later with DMP
■
Sun Enterprise Server Alternate Pathing (AP) 2.3.1
■
Sun StorEdge Component Manager 2.1 and later
■
StorTools™ 3.3 Diagnostics
■
Sun Cluster 2.2 and 3.0 software (see “Sun Cluster Support” on page 10)
■
Sun StorEdge Data Management Center 3.0
■
Sun StorEdge Instant Image 2.0
■
Sun StorEdge Network Data Replicator (SNDR) 2.0
■
Solstice Backup™ 5.5.1
■
Solstice DiskSuite™ 4.2 and 4.2.1
Tip –
For the latest information on supported software, refer to the storage solutions
web site at http://www.sun.com/storage and look for details on the Sun
StorEdge T3 array product family.
Sun Cluster Support
Sun StorEdge T3 and T3+ arrays are supported in Sun Cluster configurations with
the following restrictions:
■
Array controller firmware version 1.17b or later is required on each Sun StorEdge
T3 array.
■
Array controller firmware version 2.0 or later is required on each Sun StorEdge
T3+ array.
■
Workgroup configurations are supported in Sun Cluster 2.2 for the Sun StorEdge
T3 array only. Sun Cluster 3.0 environments support both Sun StorEdge T3 and
T3+ array models.
■
Enterprise configurations are supported only in Sun Cluster 3.0 environments.
■
Partner groups in a Sun Cluster environment must use Sun StorEdge Traffic
Manager software for multipathing support.