beautypg.com

Figure 3-1 – Sun Microsystems Sun StorEdge T3 User Manual

Page 36

background image

24

Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001

FIGURE 3-1

Sun StorEdge T3 Array Partner Group

Note –

Sun StorEdge T3 arrays require a media-interface adapter (MIA) connected

to the Fibre Channel port on the controller card to connect the fiber-optic cable. Sun
StorEdge T3+ array configurations support direct FC-AL connections.

When two units are connected together, they form a redundant partner group. This
group provides controller redundancy. Because the controller is a single point of
failure in a standalone configuration, this redundancy allows an application host to
access data even if a controller fails. This configuration offers multipath and LUN
failover features.

The partner group connection also allows for a single point of control. The bottom
unit will assume the role of the master, and from its Ethernet connections, it will be
used to monitor and administer the unit installed above it.

The master controller unit will set the global variables within this storage system,
including cache block size, cache mode, and cache mirroring.

Note –

For information about setting or changing these parameters, refer to the Sun

StorEdge T3 and T3+ Array Administrator’s Guide.

Application host

FC-AL connection

Interconnect
cables

LAN

Ethernet port

Ethernet
connection

Management host

Host-bus adapters

Ethernet
connection

Master

Alternate
master

controller
unit

controller
unit