Chapter 4

Configuration Examples

31

Single Host With Four Controller Units
Configured as Two Partner Groups

FIGURE 4-4

shows one application host connected through FC-AL cables to four

arrays configured as two separate partner groups. This configuration can be used for
capacity and I/O throughput requirements. Host-based Alternate Pathing software
is required for this configuration.

Note –

This configuration is a recommended enterprise configuration for RAS

functionality because the controller is not a single point of failure.

The following three parameters must be set on the master controller unit, as follows:

mp_support

= rw or mpxio

cache mode

= auto

cache mirroring

= auto

For information on setting these parameters, refer to the Sun StorEdge T3 and T3+
Array Administrator’s Guide
.

FIGURE 4-4

Single Host With Four Controller Units Configured as Two Partner Groups