Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001
Dual Hosts With Two Switches and Eight
Controller Units
shows two application hosts connected through FC-AL cables to two
switches and eight Sun StorEdge T3+ arrays. This multi-initiator configuration, can
be used for footprint and I/O throughput.
Note –
This configuration is not a recommended for RAS functionality because the
controller is a single point of failure.
The following limitations should be evaluated when proceeding with this
configuration:
■
Avoid the risk caused by any array or data path single point of failure using host-
based mirroring software such as VERITAS Volume Manager or Solaris Logical
Volume Manager.
■
When configuring more than a single array to share a single FC-AL loop, as with
a hub, array target addresses need to be set to unique values.
Each array needs to be assigned a unique target address using the port set
command. These target addresses can be any number between 1 and 125. At the
factory, the array target addresses are set starting with target address 1 for the
bottom array and continuing to the top array. Use the port list command to
verify that all arrays have a unique target address. Refer to Appendix A of the Sun
StorEdge T3 and T3+ Array Administrator’s Guide for further details.
The following two parameters must be set on the master controller unit, as follows:
■
cache mode = auto
■
cache mirroring = auto
Note –
For information on setting these parameters, refer to the Sun StorEdge T3 and
T3+ Array Administrator’s Guide.