Datasheet – SMSC LAN91C111 User Manual
Page 28
10/100 Non-PCI Ethernet Single Chip MAC + PHY
Datasheet
Revision 1.91 (08-18-08)
28
SMSC LAN91C111 REV C
DATASHEET
* These 5B codes are not used. For decoder, these 5B codes are decoded to 4B 0000. For encoder,
4B 0000 is encoded to 5B 11110, as shown in symbol Data 0.
The 4B5B decoder detects SSD, ESD and codeword errors in the incoming data stream as specified
in IEEE 802.3. These errors are indicated by asserting RX_ER output while the errors are being
transmitted across RXD[3:0], and they are also indicated in the serial port by setting SSD, ESD, and
codeword error bits in the PHY MI serial port Status Output register.
Manchester Decoder - 10 Mbps
In Manchester coded data, the first half of the data bit contains the complement of the data, and the
second half of the data bit contains the true data. The Manchester decoder in the LAN91C111 converts
the Manchester encoded data stream from the TP receiver into NRZ data for the controller interface
by decoding the data and stripping off the SOI pulse. Since the clock and data recovery block has
already separated the clock and data from the TP receiver, the Manchester decoding process to NRZ
data is inherently performed by that block.
3
Data 3
10101
0011
4
Data 4
01010
0100
5
Data 5
01011
0101
6
Data 6
01110
0110
7
Data 7
01111
0111
8
Data 8
10010
1000
9
Data 9
10011
1001
A
Data A
10110
1010
B
Data B
10111
1011
C
Data C
11010
1100
D
Data D
11011
1101
E
Data E
11100
1110
F
Data F
11101
1111
I
Idle
11111
0000
J
SSD #1
11000
0101
K
SSD #2
10001
0101
T
ESD #1
01101
0000
R
ESD #2
00111
0000
H
Halt
00100
Undefined
---
Invalid codes
All others*
0000*
Table 7.1 4B/5B Symbol Mapping (continued)
SYMBOL NAME
DESCRIPTION
5B CODE
4B CODE