Table 14.4 link pulse timing characteristics, Datasheet – SMSC LAN91C111 User Manual
Page 123
10/100 Non-PCI Ethernet Single Chip MAC + PHY
Datasheet
SMSC LAN91C111 REV C
123
Revision 1.91 (08-18-08)
DATASHEET
Table 14.4 Link Pulse Timing Characteristics
SYM
PARAMETER
LIMIT
UNIT
CONDITIONS
MIN
TYP
MAX
t42
NLP Transmit Link Pulse Width
See
nS
t43
NLP Transmit Link Pulse Period
8
24
mS
t44
NLP Receive Link Pulse Width Required
For Detection
50
nS
t45
NLP Receive Link Pulse Minimum Period
Required For Detection
6
7
mS
link_test_min
t46
NLP Receive Link Pulse Maximum
Period Required For Detection
50
150
mS
link_test_max
t47
NLP Receive Link Pulse Required To
Exit Link Fail State
3
3
3
Link
Pulses
lc_max
t48
FLP Transmit Link Pulse Width
100
150
nS
t49
FLP Transmit Clock Pulse to Data Pulse
Period
55.5
62.5
69.5
μS
interval_timer
t50
FLP Transmit Clock Pulse to Clock Pulse
Period
111
125
139
μS
t51
FLP Transmit Link Pulse Burst Period
8
22
mS
transmit_link_burst_time
r
t52
FLP Receive Link Pulse Width Required
For Detection
50
nS
t53
FLP Receive Link Pulse Minimum Period
Required For Clock Pulse Detection
5
25
μS
flp_test_min_timer
t54
FLP Receive Link Pulse Maximum
Period Required For Clock Pulse
Detection
165
185
μS
flp_test_max_timer
t55
FLP Receive Link Pulse Minimum Period
Required For Data Pulse Detection
15
47
μS
data_detect_min_timer
t56
FLP Receive Link Pulse Maximum
Period Required For Data Pulse
Detection
78
100
μS
data_detect_max_timer
t57
FLP Receive Link Pulse Burst Minimum
Period Required For Detection
5
7
mS
nlp_test_min_timer
t58
FLP Receive Link Pulse Burst Maximum
Period Required For Detection
50
150
mS
nlp_test_max_timer
t59
FLP Receive Link Pulses Bursts
Required To Detect AutoNegotiation
Capability
3
3
3
Link
Pulses