SpeedStream Powerline Wireless Router User Guide
16
LAN Screen
Use the LAN link on the main menu to reach the LAN screen. An example screen is shown 
below: 
Figure 6: LAN Screen
Data - LAN Screen
TCP/IP
IP Address
IP address for the SpeedStream Powerline Wireless Router, as seen 
from the local LAN. Use the default value unless the address is al-
ready in use or your LAN is using a different IP address range. In the 
latter case, enter an unused IP Address from within the range used by 
your LAN. 
Subnet Mask
The default value 255.255.255.0 is standard for small (class "C") 
networks. For other networks, use the Subnet Mask for the LAN 
segment to which the SpeedStream Powerline Wireless Router is 
attached (the same value as the PCs on that LAN segment). 
DHCP Server
•
If Enabled, the SpeedStream Powerline Wireless Router will 
allocate IP Addresses to PCs (DHCP clients) on your LAN when 
they start up. The default (and recommended) value is Enabled. 
•
If you are already using a DHCP Server, this setting must be 
Disabled, and the existing DHCP server must be re-configured to 
treat the SpeedStream Powerline Wireless Router as the Gateway. 
See the following section for further details. 
•
The Start IP Address and Finish IP Address fields set the values 
used by the DHCP server when allocating IP Addresses to DHCP 
clients. This range also determines the number of DHCP clients 
supported. 
See the following section for further details on using DHCP.
Buttons
Save
Save the data on screen.
Cancel
The "Cancel" button will discard any data you have entered and reload 