2 steps prior to some procedures – SATO CL 408e User Manual
Page 76
Page 4-2
Section 4. Electric Checks and Adjustments
SATO CL408e/CL412e Service Manual
PN 9001078
Rev. B
4.2 Steps Prior to Some Procedures
Some adjustments in this section require access to potentiometers and the test point
connector located on the main PCB. Raise the door and remove the LH cover for
accessing the main PCB.
RAISE THE TOP ACCESS
DOOR AND REMOVE (2)
SCREWS HOLDING THE SIDE
COVER TO THE FRAME
REMOVE (2) SCREWS
HOLDING THE SIDE COVER
TO THE OUTSIDE FRAME
STEP
PROCEDURE
1.Turn the printer OFF and disconnect the AC power cord.
2.Raise the access door and remove (2) screws holding the
electronics side cover to the inside frame.
3.Remove (2) screws holding the electronics side cover to the
outside frame. Lift off the cover to expose the main PCB.
Refer to the appropriate section to begin adjustments.
ELECTRONICS
COMPARTMENT
REMOVE SIDE
COVER