Advanced mode, Counters mode, Counters hd dsp cut life – SATO CL 408e User Manual
Page 52: Lcd panel — counters mode
Page 2-32
Section 2. Configuration
SATO CL408e/CL412e Service Manual
PN 9001078
Rev. B
STEP
PROCEDURE
1.
Use the LINE key to step the underlined cursor to the desired counter,
the Head (HD) counter or the LIFE counter. The default position is
the Head Counter.
2.
Press the FEED key to display the current value (in meters) stored in
the counter.
3.
Press the FEED key to advance to the next screen.
LCD Panel — Counters Mode
STEP
PROCEDURE
1.
Press the LINE key while simultaneously turning the power on.
When the printer emits one long beep, release the LINE key to display
the first screen.
2.
Press the LINE key 3X to advance to the Counters Mode.
3
.
Press the FEED key to advance the display to the counters selections.
The Counters Mode is provided to allow the user to access the internal printer counters
and is entered from the Advanced Mode.
ADVANCED MODE
To Enter Advanced Mode:
counters mode
The counters are identified in the display as:
HD: Head Counter (should be reset when print head is replaced)
DSP: Dispense Counter
CUT: Cutter Counter
LIFE: Life Counter (cannot be reset)
Counters
hd dsp cut life
Counters
HD
DSP CUT LIFE
head counter
xxxxx m
head Count clear
Yes
no