Power up menu – Siemens PSFR-CP41 User Manual
Page 44
U42093-J-Z716-1-74
Operating Manual
Configuring the PSFR-CP41
Power Up Menu
Power Up Menu
When you turn the PSFR-CP41’s power switch, a series of messages similar to
the following appear:
If you do not see messages on your screen, re-check your computer’s serial
port settings and press Enter five or six times. In particular, make sure the
baud rate is set to one of the values listed in Table “Connection properties”.
The default boot mode is 1) Fibre Channel/SCSI Router and will be automati-
cally selected if you wait three seconds. The main menu appears:
The main menu allows for various operations to be performed on the PSFR-
CP41.
Performing Power-on Self Test …
Monitor-flash Check-sum .................................. passed
Program-store Main RAM.................................... passed
Trace Buffer in Main RAM.................................. passed
PCI Protocol RAM (4mb).................................... passed
SCSI Script RAM........................................... passed
Initializing Ports..
Fibre-channel Port Single-frame Sequence Loopback......... passed
Fibre-channel Port Single-frame Sequence Loopback......... passed
Ethernet Port Loopback.................................... passed
SCSI Port Loopback........................................ passed
Self test completed successfully
Select which mode to boot :
1.
Fibre Channel / SCSI Router
2.
Diagnostics Monitor
i
Crossroads Systems CP4100 Configuration
Version: X.X XXXX
1) Perform Configuration
2) Display Status of Power-on Self Test
3) Display Trace and Assertion History
4) Reboot
5) Download a New Revision of the Firmware
Command >