(4)

Outdoor Fan Speed Control

1)

C4232 Type

• In low outdoor temperature, the outdoor fan is set automatically from HIGH to LOW to

prevent the indoor heat exchanger from freezing.

• When the outdoor temperature falls below 78

°

F, the outdoor fan is set from HIGH to

LOW automatically. When the outdoor temperature rises to 82

°

F, the outdoor fan is

set from LOW to HIGH automatically.

2)

CL4232 Type

• In low outdoor temperature, the outdoor fan is set automatically from HIGH to MED,

LOW to prevent the indoor heat exchanger from freezing.

• When the outdoor temperature falls below 77

°

F, the outdoor fan is set from HIGH to

MED automatically. When the outdoor temperature rises to 81

°

F, the outdoor fan is

set from MED to HIGH automatically.

• When the outdoor temperature falls below 59

°

F, the outdoor fan is set from MED to

LOW automatically. When the outdoor temperature rises to 63

°

F, the outdoor fan is

set from LOW to MED automatically.

• When the outdoor temperature falls below 47

°

F, the outdoor upper fan is set from

LOW to OFF and Lower fan is set from LOW to MED antomatically. When the outdoor
temperature rises to 50

°

F, the outdoor upper fan is set from OFF to LOW and Lower

fan is set from MED to LOW antomatically.

870

380

230

FAN ROTATION RPM

Upper fan: OFF
Lower fan: M

Upper fan: M
Lower fan: M

Upper fan: H
Lower fan: H

Upper fan: L
Lower fan: L

47

50

59

63

77

81

OUTDOOR AIR TEMPERATURE

°

F DB