beautypg.com

Electrical data – Sanyo CL4232 User Manual

Page 38

background image

– 38 –

SM830078

9. ELECTRICAL DATA

Indoor Unit

Outdoor Unit

Complete Unit

Fan Motor

Fan Motor

Compressor

Performance at

230 - 208 V / 1 phase / 60 Hz

230 - 208 V / 1 phase / 60 Hz

Rating conditions

A

0.9 - 0.8

1.8 - 1.8

18.1 - 18.5

20.8 - 21.1

kW

0.2 - 0.16

0.36 - 0.34

3.67 - 3.62

4.23 - 4.12

Full load conditions

A

0.9 - 0.8

1.8 - 1.8

21.44 - 22.7

24.1 - 25.3

kW

0.2 - 0.16

0.36 - 0.34

4.49 - 4.48

5.05 - 4.98

Starting amperes

A

1 - 1

2 - 2

131 - 131

134 - 134

Electrical characteristics

Indoor model: XS4232 / Outdoor model: C4232, CL4232

Indoor Unit

Outdoor Unit

Complete Unit

Fan Motor

Fan Motor

Compressor

Performance at

230 - 208 V / 1 phase / 60 Hz

230 - 208 V / 1 phase / 60 Hz

Rating conditions

A

0.7 - 0.7

1.8 - 1.8

18.1 - 18.5

20.6 - 21.0

kW

0.16 - 0.14

0.36 - 0.34

3.67 - 3.62

4.19 - 4.10

Full load conditions

A

0.7 - 0.7

1.8 - 1.8

21.44 - 22.7

23.9 - 25.2

kW

0.16 - 0.16

0.36 - 0.34

4.49 - 4.48

5.01 - 4.96

Starting amperes

A

1 - 1

2 - 2

131 - 131

134 - 134

Rating Conditions

: Indoor Air Temperature

80

°

F DB / 67

°

F WB

Outdoor Air Temperature

95

°

F DB

Full Load Conditions : Indoor Air Temperature

80

°

F DB / 67

°

F WB

Outdoor Air Temperature 115

°

F DB

Indoor model: TS4232 / Outdoor model: C4232, CL4232