beautypg.com

Specifications, 2) major component specifications (a) indoor unit – Sanyo CL4232 User Manual

Page 10

background image

– 10 –

SM830078

(2)

Major Component Specifications

(A)

Indoor Unit

2. SPECIFICATIONS

DATA SUBJECT TO CHANGE WITHOUT NOTICE

MODEL No.

XS4232

Source

230 - 208 V / 1 phase / 60 Hz

Remote controller (Accessory)

RCS - 5PS4U

Controller P. C. B Ass'y

CR - TS2432

Control circuit fuse

250 V, 3 A

Switch Ass'y

SW - X363GS

Fan (Number … diameter)

in.

(mm)

Turbo (1…19-9/32 (490))

Fan motor

Model

SFG6X - 61A3P

Source

230 - 208 V / 1 phase / 60 Hz

No. of pole … r.p.m. (230 V, High)

rpm

6 … 560

Nominal output

W

60

Coil resistance

BRW - WHT

:

71.1

,

ORG - YEL

:

22.7

(Ambient temperature 68

°

F)

WHT - VLT

:

8.7

,

VLT

- PNK

:

43.2

VLT

- ORG

:

13.3

,

YEL

- BLK

:

54.32

Safety device

Operating temperature

Open

°

F

266

±

14.4

Close

°

F

174.2

±

27

Run capacitor

VAC,

µ

F

440 V , 6

µ

F

Heat exchanger

Coil

Aluminum plate fin / Copper tube

Rows … Fins per inch

2 … 14.9

Face area

ft.

2

(m

2

)

5.17 (0.48)

Panel

Model No.

PNR - XS3632

Indicator Lamp Ass'y

IND - XS3632

Auto louver motor

MT8 - 3C

Auto louver motor … Rated

V, W,

rpm

240 VAC , 3 W , 3 rpm

Coil resistance (Ambient temperature 77

°

F)

16,430

±

8 %

This manual is related to the following products: