8. INSTALLATION INSTRUCTIONS

Out-
door
unit

Heat source

Hot air

Exhaust fan

0591_C_I

Fig. 2

Fig. 3

Min.
1 inch

Min.
1 inch

Min. 2 ft.

4 in.

0931_C_I

Min.
7 ft.

Ground

Air
dis-
charge

0932_C_I

Obstacle above

Outdoor Unit

AVOID:

heat sources, exhaust fans, etc. (Fig. 2)

damp, humid or uneven locations.

DO:

choose a place as cool as possible.

choose a place that is well ventilated and
outside air temperature does not exceed
maximum 115

°

F constantly.

allow enough room around the unit for air
intake/ exhaust and possible mainte-
nance. (Fig. 3)

provide a solid base; about 6 inch above
ground level to reduce humidity and
possible water damage in the unit and
decreased service life. (Fig. 4)

use lug bolts or equivalent to bolt down
unit, reducing vibration and noise.

In case of multiple installations

Air in

Air in

Air
discharge

Concrete block
4 inch

×

1 ft. 4 inch

beams or equal

Anchor bolts
(4 pieces)

Min. 6 inch

0934_C_I

Unit spacing if air discharge chamber is not used.

Unit spacing when air discharge chamber is used.

Min. 4 ft.

Min. 4 ft.

Min. 5 ft.

Min. 1 ft.

Min. 12 ft.

Min. 8 inch

Min. 4 ft.

Min. 8 inch

Min. 4 ft.

Min. 1 ft. 2 inch

Min. 1 ft. 2 inch

Min. 1 ft.

Min. 1 ft.

Air
discharge
chamber

If you would like to make the separation smaller on the air
discharge side, use an air discharge chamber.
You can install any number of units side-by -side.

Only up to 3 units can be installed side-by-side under the above
conditions. The next group must be spaced at least 1 ft. away
from the first group.

0933_C_S

Fig. 4