beautypg.com

Appendix, 1 status specifications, 1-1 enq command status – Star Micronics Dot Impact Printer User Manual

Page 91: 1-2 eot command status

background image

5-1

STAR Command Specifications

Rev. 0.70

5. APPENDIX

5-1 Status Specifications

This function is effective only when using an interface capable of bi-directional data communications.
Refer to your printer’s product specification manual to verify if the interface cable on the printer you use is capable of
bi-directional data communications.

5-1-1 ENQ Command Status

This status is the one the printer transmits using the ENQ command.

Bit Contents

Status

By model

“0”

“1”

BD100

SP2000

BD500

SP500

SP700

7

Compulsion SW

Open

Closed

6

Buffer overflow

No error

Overflow

5

Reception Buffer
Empty

Has Data

Empty

4

Fixed at “0”

-

-

-

-

-

-

3

Paper end

Paper

No paper

2

Mechanical Error

No Error

Error

1

Framing Error

No Error

Error

0

Parity Error

No Error

Error

• Framing error/parity error
These errors occur when using a serial I/F.(For anything other than a serial interface, always Bit 0 = Bit 1 = 0.)
With these errors, the information at that time is held and the error status is sent when there is an inquiry of the status
by this command.
• Compulsion SW
When the conversion switch is ON, Bit 7 = 1.

5-1-2 EOT Command Status

This status is the one the printer transmits using the EOT command.

Bit Contents

Status

By model

“0”

“1”

BD100

SP2000

BD500

SP500

SP700

7

-

-

-

-

-

6

-

-

-

-

-

5

-

-

-

-

-

4

Fixed at “1”

-

-

-

-

-

-

3

Paper end

Paper

No paper

2

Paper near-end

Paper

No paper

x

x

1

Black mark detection
error

No Error

Error

x

x

0

Fixed at “0”

-

-

-

-

-

-

• Paper end

Same as the ENQ status Bit 3

• Bit 5 to 7 states are unknown