Alarm Output

Item

Function/Set Value

This section describes the setting procedures for alarm output.
Set Values : ON, OFF

Select the alarm output method.
Output OFF : Output alarm signals when the Alarm Output 1

or Alarm Output 2 terminal is connected to the
GND terminal.

Output ON : Output alarm signals when the Alarm Output 1

or Alarm Output 2 terminal and the GND terminal
are disconnected from each other.

Level

: Continue output of alarm signals throughout the

alarm input process.

Momentum : Output alarm signals only at the specified time.

Specify time using the Return Interval item.

For setting the output interval when the Output Pattern item is
set to Momentum.
This is disabled when the Output Pattern item is set to Level.

Upon pressing the Output button, alarm signal output will be
sent from the alarm output terminal on the ceiling mount.
This is used for checking the alarm operation.

Initial Value

OFF

6

Output 1/
Output 2

Output Value

Pattern

Interval

7

Output 1
force output/
Output 2
force output

2-4 Other Settings Using the "VN-C205U Setup Tool" (4. Alarm Setting) (Continued)

Settings (Step 2 Network Settings)

Other Triggers

Item

Function/Set Value

For setting alarm operations when motion is detected within
the area specified in the motion detection settings.

* Please refer to the [Alarm 1/2] item for details on the set val-

ues.

Initial Value

*Please

refer to
the [Alarm
1/2] item
for the
initial
values.

5

Motion Detection

• Mode
• Alarm Output
• Message Packet
• Alarm FTP

Note

Output is disabled when the Output Pattern item is set
to "Level".

C205_p27-45

05.6.28, 11:45 AM

44