Cisco Systems Intelligent Gigabit Ethernet Switch Modules for the IBM BladeCenter, Software Configuration Guide

24R9746

Chapter 4 Administering the Switch

Managing the MAC Address Table

To disable the switch from sending MAC address notification traps, use the no snmp-server enable
traps
mac-notification global configuration command. To disable the MAC address notification traps
on a specific interface, use the no snmp trap mac-notification {added | removed} interface
configuration command. To disable the MAC address notification feature, use the no mac address-table
notification
global configuration command.

This example shows how to specify 172.20.10.10 as the NMS, enable the switch to send MAC address
notification traps to the NMS, enable the MAC address notification feature, set the interval time to
60 seconds, set the history-size to 100 entries, and enable traps whenever a MAC address is added on
the specified port.

Switch(config)# snmp-server host 172.20.10.10 traps private

Switch(config)# snmp-server enable traps mac-notification

Switch(config)# mac address-table notification

Switch(config)# mac address-table notification interval 60

Switch(config)# mac address-table notification history-size 100

Switch(config)# interface fastethernet0/4

Switch(config-if)# snmp trap mac-notification added

You can verify the previous commands by entering the show mac address-table notification interface
and the show mac address-table notification privileged EXEC commands.

Step 5

mac address-table notification [interval value] |
[history-size value]

Enter the trap interval time and the history table size.

(Optional) For interval value, specify the
notification trap interval in seconds between
each set of traps that are generated to the NMS.
The range is 0 to 2147483647 seconds; the
default is 1 second.

(Optional) For history-size value, specify the
maximum number of entries in the MAC
notification history table. The range is 0 to 500;
the default is 1.

Step 6

interface interface-id

Enter interface configuration mode, and specify the
interface on which to enable the SNMP MAC
address notification trap.

Step 7

snmp trap mac-notification {added | removed}

Enable the MAC address notification trap.

Enable the MAC notification trap whenever a
MAC address is added on this interface.

Enable the MAC notification trap whenever a
MAC address is removed from this interface.

Step 8

end

Return to privileged EXEC mode.

Step 9

show mac address-table notification interface

show running-config

Verify your entries.

Step 10

copy running-config startup-config

(Optional) Save your entries in the configuration file.