Chapter 6. Compliance subsystem implementation

169

The operational parameters listed above accept multiple values, so edit the
appropriate parameters by selecting the proper tabs and adding all the
versions accepted in your environment. To add additional values to the
parameter click the plus (+) sign. To remove the value click the minus (-) sign.

As opposed to the collectors described above, we

must change

the name of

the workflow for collector nac.win.any.oslevel.PostureOSLevelV2. The
solution was originally developed in Japan, so the default value for the
SERVICE_PACK_WF parameter is
TCRMSServicePackInstall_WinXpSp2Jp. Change this value to
TCRMSServicePackInstallWinXPSP2.

When you are done editing click Save.

7. The next policy we customize is the one that checks for appropriate hotfixes

installed on the client workstation.

WARN_WINDOWS_2000

Operational

List of service packs that generate
warnings for the Microsoft Windows
2000 operating system

PASS_WINDOWS_2003

Operational

List of accepted service packs for
the Microsoft Windows 2003
operating system

WARN_WINDOWS_2003

Operational

List of service packs that generate
warnings for the Microsoft Windows
2003 operating system

PASS_WINDOWS_XP

Operational

List of accepted service packs for
the Microsoft Windows XP operating
system

WARN_WINDOWS_XP

Operational

List of service packs that generate
warnings for the Microsoft Windows
XP operating system

SERVICE_PACK_WF

Workflow

Name of the workflow used for
remediation if a service pack needs
to be installed

Important: The paragraph below is different than for other collectors, so
read carefully.

Parameter name

Parameter type

Description