56K V.92 Data, Fax, and Voice Chipset

Programmer’s Guide

Intel Confidential

41

The escape character is determined by the value stored in S-register S2, and it is typically a ‘

+’

character. The following is an example of the TIES Escape Sequence:

Format:

char1 = char2 = char3 = escape character (S2)

Example:

DTE:

+++ AT

DCE:

OK

Note:

TIES requires that the three-character escape sequence be contiguous and not repeated. The
character immediately preceding the first character of the three-character sequence cannot be the
same as the escape character. Therefore, “+++ AT ” is valid, but “++++ AT ” is not.

Table 3-4.

Data Mode Command Descriptions

Note:

** denotes the factory-default setting.

Command

Default

Description

A/

none

Repeat Last Command: This command re-executes the last AT command string
stored in the command buffer. A/ is the only command not preceded by AT and end-
ed by a carriage return.

Sending any character (such as a carriage return) after A/ and before a modem re-
sponse is sent to the DTE causes the modem to abort the remainder of the com-
mand string in the modem internal command buffer.

A

none

Answer Command: This command causes the modem to immediately go
off-hook and initiate an answer mode handshake without waiting for an in-
coming ring signal. This command is useful for manually answering a call or
establishing a back-to-back connection with an originate-mode modem.