beautypg.com

4 auxiliary and applied functions, 2) watch data – MITSUBISHI ELECTRIC MOTION CONTROLLERS Q172DCPU User Manual

Page 96

background image


4 - 5

4 AUXILIARY AND APPLIED FUNCTIONS

(2) Watch data

(a) This data is used to perform the limit switch output function. This data is

comparison data to output the ON/OFF signal. The output device is
ON/OFF-controlled according to the ON region setting.

(b) As the watch data, motion control data or optional word device data can be

used.

1) Motion control data

Axis No. setting range

Item Unit

Data

type

Q173DCPU Q172DCPU

Feed current value
Real current value

Position command

Deviation counter value

PLS

32-bit

integer type

Motor current

0.1%

16-bit

integer type

Motor speed

0.1r/min

Cam shaft within-one-revolution current value
Feed current value (Virtual)
After-differential current value (Virtual)

1 to 32

1 to 8

After-differential encoder current value
Encoder current value

PLS

32-bit

integer type

1 to 12

1 to 8

2) Word device data

Item

Device No. setting range

Data register

D0 to D8191

Link register

W0 to W1FFF

Motion register

#0 to #7999

Multiple CPU area device

U \G10000 to U \G (10000+p-1)

(Note-1)

(Note-1) : "p" indicates the user setting area points of the Multiple CPU high speed

transmission area for the each CPU.

3) When the optional device data is set, the following data type is set as the

data type to be compared.

Data type

Remarks

16-bit integer type

32-bit integer type
64-bit floating-point type

Set the device No. as an even No..