3 - 2

3 COMMON PARAMETERS

3.1.1 System data settings

The table below lists the system data items to be set.

Item

Setting

range

Initial

value

Remark

Main base

8/12 slots

Main base: 8 slots

Base setting

Extension base

None/2/3/5/8/10/12 slots

None

Set the number of slots in the main
base or extension base.

No. of CPU

2/3/4 modules

2 modules

Set the total number of Multiple
CPUs including PLC CPU(s).

Error operation mode at the
stop of CPU

Stop/do not stop all CPUs upon an
error in CPU No. 1 to 4.
(The setting range varies depending
on the number of Multiple CPUs.)

Stop all CPUs upon error
in CPU Nos. 1 to 4

Set whether or not to stop the entire
system when a CPU stop error
occurs in each CPU.

CPU
specific
send range

0 to 14k points

Varies depending on the
number of CPUs.

System
area

1 to 2k points

1

Multiple CPU
high speed
transmission
area setting

Automatic
refresh
setting

Point : 2 to 14336 points
Start : Set target device for

automatic refresh.

None

Refer to Section 2.3.2.

Multiple CPU
setting

Multiple CPU synchronous
startup setting

Set/do not set CPU No. 1 to 4 as the
synchronized startup.
(The setting range varies depending
on the number of Multiple CPUs.)

Set CPU No. 1 to 4 as
the synchronized startup.

Refer to Section 2.3.5.

Module arrangement

Within the main base and extension
base slots

None

Install the modules controlled by the
self CPU in the main base and/or
extension base(s).

Common
system
parameters

Motion slot
setting

Individual module

Varies depending on the module.

Varies depending on the
module.

Set detailed items for each module
controlled by the self CPU.

Operation cycle

0.4ms/0.8ms/1.7ms/3.5ms/7.1 ms/
14.2ms/Auto

Auto

Set the operation cycle of motion
control.

Operation at STOP to RUN

M2000 is turned on by switching
from STOP to RUN./M2000 is
turned on by switching from STOP
to RUN and setting 1 in the set
register.

M2000 is turned on by
switching from STOP to
RUN.

Set the condition in which the PLC
ready flag (M2000) turns on.

Forced stop

(Note-1)

None/X(PX) (0 to 1FFF)/
M (0 to 8191)

None

Set the bit device to use forced stop
in the program.
However, the forced stop input by
EMI terminal of Motion CPU module
cannot be invalidated using
parameter setting.

System basic
setting

Latch range

M (0 to 8191)/B (0 to 1FFF)/
F (0 to 2047)/D (0 to 8191)/
W (0 to 1FFF)

None

Set the latch range of device
memory.

Individual
parameters

Self CPU installation position setting

Set self CPU/other CPU/CPU
(empty) for slots 0/1/2. (The setting
range varies depending on the
number of Multiple CPUs installed.)

None

Set the installation position of the
self CPU in the main base.