4 AUXILIARY AND APPLIED FUNCTIONS


(1) Self CPU program which connects/disconnects servo amplifiers from Axis 5 on

Disconnect procedure: Turn OFF the power supply of servo amplifier after

checking its LED display for "AA".

Connect procedure: Resume operation of servo amplifier after verifying

that the servo ready (M2415+20n) is ON.

Disconnect processing

Connect processing

(a) Motion SFC program

Disconnect operation

Connect operation

[G10]

[F10]

[G20]

[F20]

[G30]

[G10]

[F10]

[G20]

[F20]

[G30]

SD508==0

SD803=5

SD508==-1

SD803=-2

SD508==0

END

SD508==0

SD803=-10

SD508==-1

SD803=-2

SD508==0

END

Check the disconnect
command accept status.

Set "5" (Disconnect from
Axis 5 on) as disconnect
command in SD803.

Disconnect execute waiting

Set "-2" as disconnect
execute command in
SD803.

Check the completion of
disconnect processing.

Check the connect
command accept status.

Set "-10" as connect
command in SD803.

Connect execute waiting

Set "-2" as connect
execute command in
SD803.

Check the completion of
connect processing.

Q61P QnUD(H)

CPU

Q172D
CPU

QY40

QY40

Q172D
LX

QY40

System configuration

Axis 1

AMP

M

Axis 2

AMP

M

Axis 3

AMP

M

Axis 4

AMP

M

Axis 5

AMP

M

Axis 8

AMP

M

Disconnection (From Axis 5 on)


This manual is related to the following products: