Caution, 6) usage methods – MITSUBISHI ELECTRIC MOTION CONTROLLERS Q172DCPU User Manual
Page 9
A - 8
(6) Usage methods
CAUTION
Immediately turn OFF the power if smoke, abnormal sounds or odors are emitted from the Motion
controller, servo amplifier or servomotor.
Always execute a test operation before starting actual operations after the program or
parameters have been changed or after maintenance and inspection.
Do not attempt to disassemble and repair the units excluding a qualified technician whom our
company recognized.
Do not make any modifications to the unit.
Keep the effect or electromagnetic obstacles to a minimum by installing a noise filter or by using
wire shields, etc. Electromagnetic obstacles may affect the electronic devices used near the
Motion controller or servo amplifier.
When using the CE Mark-compliant equipment, refer to the "EMC Installation Guidelines" (data
number IB(NA)-67339) for the Motion controllers and refer to the corresponding EMC guideline
information for the servo amplifiers, inverters and other equipment.
Use the units with the following conditions.
Conditions
Item
Q61P-A1 Q61P-A2
Q61P
Q62P
Q63P
Q64P
+10% +10%
+10%
+30%
+10%
100 to 120VAC
-15%
200 to 240VAC
-15%
100 to 240VAC
-15%
24VDC
-35%
100 to 120VAC
-15%
/
+10%
200 to 240VAC
-15%
Input power
(85 to 132VAC)
(170 to 264VAC)
(85 to 264VAC)
(15.6 to 31.2VDC)
(85 to 132VAC/
170 to 264VAC)
Input frequency
50/60Hz ±5%
Tolerable
momentary
power failure
20ms or less