3 - 20
3 COMMON PARAMETERS
(2) Gain/filter parameters
No. Symbol
Name
Initial
value Unit
PB01
FILT
Adaptive tuning mode (Adaptive filter ) 0000h
—
PB02
VRFT
Vibration suppression control tuning mode (Advanced vibration suppression control)
0000h
—
PB03
—
For manufacturer setting
0
—
PB04
FFC
Feed forward gain
0
%
PB05
—
For manufacturer setting
500
—
PB06
GD2
Ratio of load inertia moment to servomotor inertia moment
7.0
times
PB07
PG1
Model loop gain
24 rad/s
PB08
PG2
Position loop gain
37
rad/s
PB09
VG2
Speed loop gain
823 rad/s
PB10
VIC
Speed integral compensation
33.7
ms
PB11
VDC
Speed differential compensation
980
—
PB12
—
For manufacturer setting
0
—
PB13
NH1
Machine resonance suppression filter 1
4500
Hz
PB14
NHQ1
Notch shape selection 1
0000h
—
PB15
NH2
Machine resonance suppression filter 2
4500
Hz
PB16
NHQ2
Notch shape selection 2
0000h
—
PB17 —
Automatic
setting
parameter
—
—
PB18
LPF
Low pass filter setting
3141
rad/s
PB19
VRF1
Vibration suppression control - vibration frequency setting
100.0
Hz
PB20
VRF2
Vibration suppression control - resonance frequency setting
100.0
Hz
PB21
0.00
PB22
—
For manufacturer setting
0.00
—
PB23
VFBF
Low pass filter selection
0000h
—
PB24 MVS
Slight vibration suppression control selection
0000h
—
PB25
—
For manufacturer setting
0000h
—
PB26 CDP
Gain changing selection
0000h
—
PB27
CDL
Gain changing condition
10
—
PB28
CDT
Gain changing time constant
1
ms
PB29
GD2B
Gain changing - ratio of load inertia moment to servo motor inertia moment
7.0
times
PB30
PG2B
Gain changing - position loop gain
37
rad/s
PB31
VG2B
Gain changing - speed loop gain
823
rad/s
PB32
VICB
Gain changing - speed integral compensation
33.7
ms
PB33
VRF1B
Gain changing - vibration suppression control - vibration frequency setting
100.0
Hz
PB34
VRF2B
Gain changing - vibration suppression control - resonance frequency setting
100.0
Hz
PB35
0.00
PB36
0.00
PB37
100
PB38
0.0
PB39
0.0
PB40
0.0
PB41
1125
PB42
1125
PB43
0004h
PB44
0.0
PB45
—
For manufacturer setting
0000h
—
POINTS
(1) When the items marked " " in the above table has changed, make the Multiple
CPU system reset or power supply OFF to ON. And, once turn OFF the servo
amplifier power supply and then turn ON it again.