beautypg.com

4 auxiliary and applied functions – MITSUBISHI ELECTRIC MOTION CONTROLLERS Q172DCPU User Manual

Page 131

background image


4 - 40

4 AUXILIARY AND APPLIED FUNCTIONS

(2) PLC CPU program which connects/disconnects servo amplifiers from Axis 5 on

which is connected to the Motion CPU (CPU No.2).

Disconnect procedure: Turn X0 OFF to ON, and then turn OFF the power

supply of servo amplifier after checking the LED
display "AA" of servo amplifier.

Connect procedure: Turn X1 OFF to ON, and then resume operation of

servo amplifier after checking the servo ready
(M2415+20n) of servo amplifier.

0

SM400

DP.DDRD

H3E1

D100

M10

SD508

D50

K-2

D104

MOV

18

K1

D51

MOV

5

M101

M100

M102

X0

K5

D102

MOV

M100

SET

K-10

D102

MOV

D100

K0

=

M10

M11

39

M100

SET

X1

M10

M100

M12

M101

M12

M13

DP.DDWR H3E1

SD803

M12

D102

D50

M100

RST

SET

M101

RST

M102

SET

DP.DDRD

H3E1

D100

M10

SD508

D50

57

D100

K-1

=

M10

M11

78

M10

M102

M12

M103

M12

M13

DP.DDWR H3E1

SD803

M12

D104

D50

M102

RST

M103

SET

M103

RST

M104

SET

DP.DDRD

H3E1

D100

M10

SD508

D50

96

D100

K0

=

M10

M11

M10

M104

M104

RST

M101

Set "-2" as disconnect execute
command in D104.

Set "-10" as connect command
in D102.

Read the data of SD508 for Multiple
CPU system (CPU No.2) by turning
M102 ON, and store it to data area
(D100) of self CPU.

Write the data of SD803 for Multiple
CPU system (CPU No.2) to D102 by
turning M101 ON.
(Disconnect command/Connect
command)

Read the data of SD508 for Multiple
CPU system (CPU No.2) by turning
M100 ON, and store it to data area
(D100) of self CPU.

Write the data of SD803 for Multiple
CPU system (CPU No.2) to D104 by
turning M103 ON.
(Disconnect execute command)

Read the data of SD508 for Multiple
CPU system (CPU No.2) by turning
M104 ON, and store it to data area
(D100) of self CPU.

Q61P QnUD(H)

CPU

Q172D
CPU

QY40

QY40

Q172D
LX

QY40

System configuration

Axis 1

AMP

M

Axis 2

AMP

M

Axis 3

AMP

M

Axis 4

AMP

M

Axis 5

AMP

M

Axis 8

AMP

M

Disconnection (From Axis 5 on)

PLC program

Set "5" (Disconnect afrom Axis 5 on)
as disconnect command in D102.

This manual is related to the following products: