Appendices, Table 1.2 special register list (continued) – MITSUBISHI ELECTRIC MOTION CONTROLLERS Q172DCPU User Manual
Page 142
APP - 7
APPENDICES
Table 1.2 Special register list (Continued)
No. Name
Meaning
Details
Set by
(When set)
Remark
SD16
SD17
SD18
SD19
• Individual information corresponding to the diagnostic error (SD0) is stored.
• The error individual information type can be judged by SD4 (individual
information category code).
5: Parameter No.
SD20
No.
Meaning
SD21
SD16
Parameter
No.
SD22
SD23
SD24
SD17
to
SD26
Empty
SD25
0401H
:Base
setting
0406H
:Motion slot setting
0E00H
:Multiple CPU setting (Number of Multiple CPU's)
0E01H
:Multiple CPU setting (Operation mode/Multiple CPU
synchronous startup)
E008H
:Multiple CPU high speed transmission area setting
(CPU specific send range setting/ (System area))
E009H/E00AH :Multiple CPU high speed transmission area setting
(Automatic refresh setting)
E00BH
:Synchronous
setting
13: Parameter No./CPU No.
No.
Meaning
SD16
Parameter
No.
SD17
CPU No.(1 to 4)
SD18
to
SD26
Empty
SD26
Error individual
information
Error individual
information
SD53
AC/DC DOWN
counter No.
Number of times
for AC/DC DOWN
• Every time the input voltage fails to or below 85[%] (AC power)/65[%] (DC
power) the rating during calculation of the Motion CPU module, the value is
incremented by 1 and stored in BIN code.
SD60 Fuse
blown
No.
Module No. with
blown fuse
• The lowest station I/O No. of the module with the blown fuse is stored.
S (Occur an error)
• The CPU switch status is stored in the following format.
B15
B12 B11
B8 B7
B4 B3
B0
1)
2)
Not used
1) CPU switch status
0: RUN
1: STOP
2) Memory card switch
Always OFF
SD200 Status of switch
Status of CPU
switch
• The CPU operating status is stored as indicated in the following figure.
B15
B12 B11
B8 B7
B4 B3
B0
1)
2)
1) Operating status of CPU
0: RUN
2: STOP
2) STOP cause
(Note) Priority is earliest first
0: RUN/STOP switch
4: Error
SD203
Operating status
of CPU
Operating status
of CPU
S (Main processing)