Magnum 6K16V Managed Fiber Switch Installation and User Guide (01/04)

51

www GarrettCom com

.

.

hooked up at the last.

When power is applied, the green PWR LED will illuminate.

Note: The GND should be hooked up first. The 6K16V unit has a floating ground, so
the user may elect to Ground either + or = terminal to suit the customer’s use.

Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or

125VDC, always use a digital voltmeter to measure the output voltage of the power
supply and determine the lead which is more “+ve potential”. The more “+ve” voltage
lead from 48V or –48V supply must be connected to the post labeled “+”.

An ON-OFF manual switch is optional for DC power. This can be used to cut

off power connections and as a RESET for the Magnum 6K16V Switch.

B4.1

UL Requirements for DC-powered units

1. Minimum 18AWG cable for connection to a Centralized DC power source.
2. Minimum 14AWG cable for connection to a earthing wiring.
3. Use only with Listed 10 A circuit breaker provided in building installation.
4. “Complies with FDA radiation performance standards, 21 CFR subchapter J.”

or equivalent.

5. Fastening torque of the lugs on the terminal block: 9 inch-pound max.
6. Centralized DC Power Source cable securement, use at least four cable ties to

secure the cable to the rac,k at least 4 inches apart, with the first one located
within 6 inches of the terminal block.

B5.0

OPERATION

Operation of Magnum 6K16V Switches with the optional -48VDC, 24VDC

and 125VDC power supply is identical to that of the standard AC-powered models.

B6.0

ORDERING INFORMATION

To order the optional -48VDC power supply factory installed, add a suffix of “-

-48VDC” after the product’s standard model # Example:

Magnum 6K16VR-48VDC.

Similarly to order the optional 24VDC or 125VDC industrial specific power

supply factory installed, add a suffix of “ 24VDC” or “125VDC” after the product ‘s

standard model #. Example: Magnum 6K16V- 24VDC, Magnum 6K16V-125VDC.

B7.0

TROUBLESHOOTING

Please refer to Section 6.0 for troubleshooting