beautypg.com

0 installation, 1locating magnum 6k16v switches, 2connecting ethernet media – GarrettCom 6K16V User Manual

Page 25

background image

Magnum 6K16V Managed Fiber Switch Installation and User Guide (01/04)

18

www GarrettCom com

.

.

3.0

Installation

Before installing the equipment, it is necessary to take the

following precautions:

1.)

If the equipment is mounted in an enclosed or multiple rack

assembly, the environmental temperature around the equipment

must be less than or equal to 50

0

C.

2.)

If the equipment is mounted in an enclosed or multiple rack

assembly, adequate air flow must be maintained for proper and

safe operation.

3.)

If the equipment is mounted in an enclosed or multiple rack

system, placement of the equipment must not overload or load

unevenly the rack system.

4.)

If the equipment is mounted in an enclosed or multiple rack

assembly, verify the equipment’s power requirements to prevent

overloading of the building/s electrical circuits.

5.)

If the equipment is mounted in an enclosed or multiple rack

assembly verify that the equipment has a reliable and

uncompromised earthing path.

This section describes installation of the Magnum 6K16V Switches, as well as

connection of the various Ethernet media types.

3.1

Locating Magnum 6K16V Switches

For vertical panel mounting and wall mounting, see Section 3.4.

For vertical DIN-Rail mounting, see Section 3.3.

For DC power options, see Appendix B. For Dual Source, see Appendix C.

For AC power input, locate an AC receptacle that is within six feet (2 meters)

of the intended Magnum 6K16V site. The rugged metal case of the Magnum 6K16V will

normally protect it from accidental damage in a lab or workplace setting. Maintain an

open view of the front to visually monitor the status LEDs. Keep an open area around

the unit so that cooling can occur from convection while the unit is in operation. The

6K16V has no fans, so it is silent when in operation. Internal electronics use the case as

a heat sink, so the unit may normally be quite warm to the touch.


3.2

Connecting Ethernet Media

The Magnum 6K16V Switches are specifically designed to support

all standard Ethernet media types within a single Switch unit. This is
accomplished by using a family of different port Modules which can be
individually selected and configured per-port. See Section 2.4 for a description
of the PMs.

The various media types supported along with the corresponding IEEE

802.3 and 802.3u standards and connector types are as follows: