beautypg.com

GarrettCom 6K16V User Manual

Page 43

background image

Magnum 6K16V Managed Fiber Switch Installation and User Guide (01/04)

36

www GarrettCom com

.

.

The following data has been collected from component manufacturer’s (Agilent’s and
Lucent’) web sites and catalogs to provide guidance to network designers and installers.

Fiber

Port

Module

Speed,

Std.

Mode

Std.
km

fdx

(hdx)

Wave

-

length

nm

Cable

Size

µm

X’mitr

Output

P

T ,

dB

R’cvr

Sens.

P

R ,

dB

Worst

OPB,

dB

Worst*

distance
Km, fdx

typical

OPB,

dB

typical*

distance

Km, fdx

6KP4V-

F10ST

10Mb

FL

Multi-

Mode

2

(2)

850 62.5/125

100/140

50/125

-15.0

-9.5

-19.5

-31

-31

-31

14

19.5

19.5

5

5.9

3.4

17

23.5

13.5

6

7

4.8

6KPV-

MST, MSC

100Mb

FX

Multi-

mode

2

(0.4)

1300 62.5/125

50/125

-20

-23.5

-31

-31

9.0

5.5

2.5

2.0

14

12

5

4

6KPV-SSC

100Mb

FX

Single-

mode

18+

(0.4)

1300

9/125

-15

-31

14

28

17.5

35

6KPV-

SSCL

100Mb

FX

Single-

mode

40

(0.4)

1300

9/125

-5

-34

29

58

32.5

65

6KPV-
MTRJ

100Mb

FX

Multi-

mode

2

(0.4)

1300 62.5/125

50/125

-20

-23.5

-31

-31

9.0

5.5

3.0

2.0

15.8

12.2

5.5

4.0

6KPV-

MLC

100Mb

FX

Multi-

mode

2

(0.4)

1300

62.5/125

-19

-31

12

4

16

5.7

6KPV-SLC

100Mb

FX

Single-

Mode

15+

(0.4)

1310

9/125

-15

-28

11

22

-

-

GBIC-

SXSC

1000Mb

Multi-

mode

0.55

1300

62.5/125

50/125

-9.5

-17

5.5

2

12.5

4

GBIC-

LXSC10

1000Mb

Single-

mode

10

1300

9/125

-9.5

-20

8.5

17

10.5

21

GBIC-

LXSC25

1000Mb

Single-

mode

25

1550

9/125

-4.0

-21

15

37.5

17.5

43

GBIC-

LXSC40

1000Mb

Single-

mode

40

1550

9/125

-4.0

-21

15

60

17.5

70

GBIC-

LXSC70

1000Mb

Single-

mode

70

1550

9/125

-3.0

-23

18

90

20.5

102

* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed

over long distances (i.e., in excess of approx. 400 meters) can be achieved

only

if the following factors are both applied:

The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the
full-duplex (factory default) setting for 100Mbps fiber ports must be used,
and

The worst-case OPB of the fiber link must be greater than the fiber cable’s
passive Attenuation.

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)