4-25
(13) Carriage unit replacement
Removal
1.
Remove the printing mechanism (Section 4.9.1 (5)), SP motor (Section 4.9.1(11)), and print head (Section
4.9.1 (14)).
2.
Mark the setting positions of the adjustment levers R and L at both sides of the mechanism. (For adjustment
lever R, see the figure on the next page.)
3.
Loosen the screw to remove the plate spring.
4.
Turn adjustment lever L counterclockwise until it contacts the belt (A).
Adjustment lever L
Belt
Plate spring
A