4-17
(6) Power supply and fuse replacement
Removal
1.
Remove the fuse from the power supply, if necessary.
2.
Disconnect AC and CNPW connectors.
3.
Remove the four screws (three screws for LA36W) then remove the power supply. The rod and its securing
screw are not used for LA36W.
Installation
Install the power supply and fuse in reverse order of removal.
Notes:
For LA36N only; before connecting the CNPW connector to the corresponding connector on the control board
(ROM board), be sure to turn the CNPW connector twice to twist the cable, fix the cable by the clamp, and wind
the cable once around the rod. If the cable wires are bound with a tie, cut the tie before winding the cable.
Fuse (*)
AC connector
Rod
(LA36N only)
CNPW connector
power supply
Rod
CNPW connector
Power supply